Home News About Us Contact Contributors Disclaimer Privacy Policy Help FAQ

Home
Search
Quick Search
Advanced
Fulltext
Browse
Collections
Persons
My eDoc
Session History
Login
Name:
Password:
Documentation
Help
Support Wiki
Direct access to
document ID:


          Display Documents



  history
ID: 251045.0, MPI für Gravitationsphysik / Laser Interferometry & Gravitational Wave Astronomy
Feedforward correction of mirror misalignment fluctuations for the GEO 600 gravitational wave detector
Authors:Smith, J. R.; Grote, Hartmut; Hewitson, Martin; Hild, Stefan; Lück, Harald; Parsons, M.; Strain, K. A.; Willke, Benno
Language:English
Date of Publication (YYYY-MM-DD):2005-07-21
Title of Journal:Classical and Quantum Gravity
Journal Abbrev.:Class. Quantum Gravity
Volume:22
Issue / Number:14
Start Page:3093
End Page:3104
Review Status:Peer-review
Audience:Not Specified
Abstract / Description:The core instrument of the GEO 600 gravitational wave detector is a Michelson interferometer with folded arms. The five main optics that form this interferometer are suspended in vacuum by triple pendulums with quasi-monolithic lower stages of fused silica. After installation of these pendulums in early 2003, a larger than expected coupling of longitudinal ground motion to tilt misalignment of the suspended optics was observed. Because of this, the uncontrolled misalignment of the optics during average conditions was several µrad Hz-1/2 in the frequency band around the pendulum resonance frequencies (0.5–4 Hz). In addition, it was found that longitudinal control signals applied to the intermediate pendulum stages also resulted in excessive mirror tilt. The resulting misalignment exceeded the level tolerable for stable operation of GEO 600. In order to reduce the level of mirror tilt, a bipartite feedforward system was implemented. One part feeds signals derived from seismic measurements to piezo-electric crystals in the stacks supporting the suspensions, reducing the longitudinal motion of the uppermost suspension points. The other applies tilt correction signals, derived from longitudinal control signals, to the intermediate level of the suspensions. The seismic feedforward correction reduces the root-mean-squared tilt misalignment of each main optic between 0.1 and 5 Hz by about 10 dB, typically. The intermediate-mass feedforward correction reduces the differential tilt misalignment of the Michelson interferometer by about 10 dB between 0.1 and 0.8 Hz, typically.
External Publication Status:published
Document Type:Article
Communicated by:Karsten Danzmann
Affiliations:MPI für Gravitationsphysik/Laser Interferometry & Gravitational Wave Astronomy
MPI für Gravitationsphysik/Observational Relativity and Cosmology
MPI für Gravitationsphysik/Teilinstitut Hannover
MPI für Gravitationsphysik/GEO 600
External Affiliations:Max Planck Inst Gravitat Phys, Albert Einstein Inst, D-30167 Hannover, Germany.; Univ Hannover, D-30167 Hannover, Germany.; Univ Glasgow, Dept Phys & Astron, Inst Gravitat Res, Glasgow G12 8QQ, Lanark, Scotland.; Dept Zool, Cambridge CB2 3EJ, England.
Identifiers:ISI:000231036000020 [ID No:1]
ISSN:0264-9381 [ID No:2]
Full Text:
You have privileges to view the following file(s):
5_14_018.pdf  [304,00 Kb] [Comment:Online Journal]  
 
The scope and number of records on eDoc is subject to the collection policies defined by each institute - see "info" button in the collection browse view.