Home News About Us Contact Contributors Disclaimer Privacy Policy Help FAQ

Home
Search
Quick Search
Advanced
Fulltext
Browse
Collections
Persons
My eDoc
Session History
Login
Name:
Password:
Documentation
Help
Support Wiki
Direct access to
document ID:


          Institute: MPI für Astronomie     Collection: Publikationen_mpia     Display Documents



ID: 709695.0, MPI für Astronomie / Publikationen_mpia
The GRAVITY spectrometers: design report of the optomechanics and active cryogenic mechanisms
Authors:Wiest, M.; Yazici, S.; Fischer, S.; Thiel, M.; Haug, M.; Araujo-Hauck, C.; Straubmeier, C.; Wank, I.; Eisenhauer, F.; Perrin, G.; Brandner, W.; Perraut, K.; Amorim, A.; Schöller, M.; Eckart, A.
Place of Publication:Bellingham, Wash.
Publisher:SPIE
Date of Publication (YYYY-MM-DD):2014
Audience:Not Specified
Abstract / Description:The work package of the University of Cologne within the GRAVITY consortium included the development and manufacturing of two spectrometers for the beam combiner instrument. Both spectrometers are optimized for different tasks. The science spectrometer provides 3 different spectral resolutions. In the highest resolution the length of the spectral lines is close to the borders of the imaging area of the detector. Also the integration time of these high resolution images is relative long. Therefor the optical pathes have to be controlled by the feedback of a faster spectrometer. The fringe tracking spectrometer has only one low resolution to allow much shorter integration times. This spectrometer provides a feedback for the control loops which stabilize the optical pathes of the light from the telescope to the instrument. This is a new key feature of the whole GRAVITY instrument. Based on the optical layout my work was the design of the mechanical structure, mountings, passive and active adjustment mechanisms. This paper gives a short review about the active mechanisms and the compliant lens mounts. They are used similarly in both spectrometers. Due to the observation and analysis of near-infrared light the mechanisms have to run at cryogenic temperatures and in a high vacuum. Except the linear stages, the motorized mechanisms will get used for several times per observation.
External Publication Status:published
Document Type:Other
Communicated by:N. N.
Affiliations:MPI für Astronomie
Identifiers:URL:http://adsabs.harvard.edu/abs/2014SPIE.9147E..2MW
The scope and number of records on eDoc is subject to the collection policies defined by each institute - see "info" button in the collection browse view.