Home News About Us Contact Contributors Disclaimer Privacy Policy Help FAQ

Home
Search
Quick Search
Advanced
Fulltext
Browse
Collections
Persons
My eDoc
Session History
Login
Name:
Password:
Documentation
Help
Support Wiki
Direct access to
document ID:


          Institute: MPI für Astronomie     Collection: Publikationen_mpia     Display Documents



ID: 710632.0, MPI für Astronomie / Publikationen_mpia
The GRAVITY spectrometers: thermal behaviour
Authors:Wank, I.; Straubmeier, C.; Wiest, M.; Yazici, S.; Fischer, S.; Eisenhauer, F.; Perrin, G. S.; Perraut, K.; Brandner, W.; Amorim, A.; Schöller, M.; Eckart, A.
Place of Publication:Bellingham, Wash.
Publisher:SPIE
Date of Publication (YYYY-MM-DD):2014
Audience:Not Specified
Abstract / Description:GRAVITY is a 2nd generation VLTI Instrument o which operates on 6 interferometric baselines by using all 4 Unit Telescopes. It will deliver narrow angle astrometry with 10muas accuracy at the infrared K-band. At the 1. Physikalische Institut of the University of Cologne, which is part of the international GRAVITY consortium, two spectrometers, one for the sciene object, and one for the fringe tracking object, have been designed, manufactured and tested. These spectrometers are two individual devices, each with own housing and interfaces. For a minimized thermal background, the spectrometers are actively cooled down to an operating temperature of 80K in the ambient temperature environment of the Beam Combiner Instrument (BCI) cryostat. The outer casings are mounted thermal isolated to the base plate by glass fiber reinforced plastic (GRP) stands, copper cooling structures conduct the cold inside the spectrometers where it is routed to components via Cu cooling stripes. The spectrometers are covered with shells made of multi insulation foil. There will be shown and compared 3 cooling installations: setups in the Cologne test dewar, in the BCI dewar and in a mock-up cad model. There are some striking differences between the setup in the 2 different dewars. In the Cologne Test dewar the spectrometers are connected to the coldplate (80K); a Cu cooling structure and the thermal isolating GRP stands are bolted to the coldplate. In the BCI dewer Cu cooling structure is connected to the bottom of the nitrogen tank (80K), the GRP stands are bolted to the base plate (240K). The period of time during the cooldown process will be analyzed.
External Publication Status:published
Document Type:Other
Communicated by:N. N.
Affiliations:MPI für Astronomie
Identifiers:ISBN:9780819496140
URL:http://cdsads.u-strasbg.fr/abs/2014SPIE.9146E..28W
The scope and number of records on eDoc is subject to the collection policies defined by each institute - see "info" button in the collection browse view.